Environmental Protection Licence Compliance

Cumulative logarithmic noise assessment for every stacked window: source levels are attenuated to the nearest sensitive receiver, combined as 10·log₁₀ Σ10^(L/10), then tested against the night-time threshold of RBL + 15 dB for the relevant Noise Catchment Area.

Stacked windows
21
Acoustic breaches
1
Windows with hard failures
4
Noise catchment areas
10

Noise Catchment Areas

Night-time Rating Background Levels and the derived EPL threshold.

NCAChainageReceiversAtten.RBLThreshold
NCA-01 Rouse Hill / Kellyville0.09.0 kmResidential403348
NCA-02 Norwest / Castle Hill9.018.0 kmMixed383651
NCA-03 Cherrybrook / Epping18.026.0 kmResidential423146
NCA-04 Macquarie Park / North Ryde26.036.0 kmCommercial344055
NCA-05 Crows Nest / North Sydney36.041.0 kmMixed363853
NCA-06 Barangaroo / Martin Place CBD41.045.0 kmCommercial304560
NCA-07 Waterloo / Sydenham45.051.5 kmResidential383550
NCA-08 Marrickville / Dulwich Hill51.557.0 kmResidential413247
NCA-09 Campsie / Belmore57.061.0 kmResidential433045
NCA-10 Punchbowl / Bankstown61.065.0 kmMixed393449

Incompatibility matrix

Tag pairs cross-referenced on every stack change. Mobile plant is additionally buffered ±0.25 km against live electrical infrastructure.

REJECTTRACTION_ISOLATION_REQUIRED×LIVE_TRACTION_REQUIRED

Traction power cannot be simultaneously isolated for OHL works and energised for CBTC dynamic testing.

REJECTLIVE_WIRE_HAZARD×TEST_TRAIN_MOVEMENT

Test train movements are prohibited through a worksite with exposed OHL conductors.

REJECTVIBRATION_SOURCE×PRECISION_MEASUREMENT

Tamping/grinding vibration invalidates balise alignment and platform screen door calibration.

REJECTHOT_WORKS×FLAMMABLE_VEGETATION

Ignition sources cannot be stacked with cut vegetation fuel loads in the corridor.

REJECTSPARK_SOURCE×FLAMMABLE_VEGETATION

Grinding spark plume presents a corridor fire risk beside cleared vegetation.

REJECTHEAVY_ON_TRACK_PLANT×TEST_TRAIN_MOVEMENT

On-track plant occupies the running line required for dynamic CBTC test runs.

SEQUENCETRACK_GEOMETRY_CHANGE×CBTC_DISRUPTION

Geometry change requires re-survey before CBTC validation; sequence these within the window.

SEQUENCEDUST_GENERATION×PRECISION_MEASUREMENT

Airborne dust degrades optical alignment accuracy.

SEQUENCEHEAVY_ON_TRACK_PLANT×HEAVY_ON_TRACK_PLANT

Two heavy on-track machines in one window contend for the same access point.

Window-by-window acoustic assessment

WindowDateNCATasksLAeqThresholdLAmaxStatus
W01-M1-NW-N1Tue, 18 Aug 01:00NCA-021475158COMPLIANT
W01-M1-CITY-N2Wed, 19 Aug 01:00NCA-071485056COMPLIANT
W01-M1-SW-N3Thu, 20 Aug 01:00NCA-081344744COMPLIANT
W01-M1-NW-N4Fri, 21 Aug 01:00NCA-031164626COMPLIANT
W02-M1-NW-N1Tue, 25 Aug 01:00NCA-031414650COMPLIANT
W02-M1-CITY-N2Wed, 26 Aug 01:00NCA-051525358COMPLIANT
W02-M1-SW-N3Thu, 27 Aug 01:00NCA-081194726COMPLIANT
W02-M1-CITY-N4Fri, 28 Aug 01:00NCA-051525358COMPLIANT
W03-M1-NW-N1Tue, 01 Sept 01:00NCA-021465151COMPLIANT
W03-M1-CITY-N2Wed, 02 Sept 01:00NCA-061556060COMPLIANT
W03-M1-SW-N3Thu, 03 Sept 01:00NCA-091244537COMPLIANT
W03-M1-SW-N4Fri, 04 Sept 01:00NCA-081434748COMPLIANT
W03-M1-CITY-WESat, 05 Sept 23:00NCA-071135023COMPLIANT
W04-M1-NW-N1Tue, 08 Sept 01:00NCA-031274636COMPLIANT
W04-M1-CITY-N2Wed, 09 Sept 01:00NCA-061236035COMPLIANT
W04-M1-SW-N3Thu, 10 Sept 01:00NCA-091444552COMPLIANT
W04-M1-NW-N4Fri, 11 Sept 01:00NCA-031424652COMPLIANT
W05-M1-NW-N1Tue, 15 Sept 01:00NCA-03248.84655EPL BREACH
W05-M1-CITY-N2Wed, 16 Sept 01:00NCA-05219.55324OTHER FAILURE
W05-M1-SW-N3Thu, 17 Sept 01:00NCA-082474751OTHER FAILURE
W06-M1-NW-N1Tue, 22 Sept 01:00NCA-022515157OTHER FAILURE